Bushings are manufactured upto 25kv, 4000A. These bushing are welded on transformer top plate and connected to transformer lead.
The various rating of bushing is given below.
Maximum voltage rating | 12 kV | ||
---|---|---|---|
Maximum current rating | 200 A | ||
Creepage Distance | 450 mm | ||
Line to ground BIL | 95 kV | ||
Open contact | 95 kV | ||
Nominal current | 10 A | ||
Dry, 1 minute with stand test | 36 kV | ||
Wet, 10 seconds with stand test | 30 kV | ||
Line to ground insulation level | 95 kV | ||
Open contact insulation level | 95 kV | ||
Nominal current | 10 A | ||
Capacitive Switching Current | 200 A | ||
Symmetric Short time Current | 4500 A for 1 Second | ||
Asymmetric Short time Current | 95000 A for 1 Second | ||
Asymmetric Making Current | 9000 A for 1 Second | ||
Dimension of OLTC | VIEWCLOSE | ||
![]() |
Rated Voltage | 11 kV |
---|---|
Maximum System Voltage | 12 kV |
Rated Current | 630 A |
Rated Short time with stand Current | 20 kA |
Rated peak with stand Current | 50 KA |
Rated Short Circuit making Current | 50 kA |
Rated breaking Current of Load with Power | 630 A |
Rated close ring breaking Current | 630 A |
Rated break Cable Charging Current | 10 A |
Rated idle load Transformer breaking | 1600 kVA |
Insulation level(rms) | 35 kV |
Mechanical lifetime(C-O cycle) | |
a)Vacuum load Switch | 10000 Nos |
b)Isolator and Earth Switch | ≥ 2000 Nos. |
Three phase simultaneous closing | ≥ 5 ms |
Maximum voltage rating | 72 kV |
Maximum current rating | 300 A |
Direction of power flow | Uni-Directional |
Tapping arrangement | Linear |
OLTC design | Single Compartment |
Maximum number of tap position | 23 |
Maximum operating step voltage | 1000 V |
Maximum operating voltage Over tapping range | 20000 V |
Maximum continuous voltage to ground | 72000 V |
Maximum continuous voltage between phases | 720000 V |
Peak emergency current | 450 A |
Weight of tap changer Without oil | 620 Kg |
Weight of tap changer with oil | 1430 Kg |
Oil content | 980 liters |
Impulse voltage between phases | 350 kVp(1.2/50 micro seconds) |
Impulse voltage between Tap changer to earth | 350 kVp(1.2/50 micro seconds) |
Impulse voltage between Adjacent contacts | 70 kVp(1.2/50 micro seconds) |
Impulse voltage across tapping Range | 200 kVp(1.2/50 micro seconds |
Maximum voltage rating | 132 kV(Graded neutral) |
Maximum current rating | 300 A |
Maximum system voltage | 85 kV |
OLTC design | Single Compartment |
Maximum number of tap position | 17 |
Maximum continuous current | 300 A |
Maximum operating step voltage | 1800 V |
Maximum operating over fine taps | 14000 V |
Maximum operating voltage over Coarse taps | 14000 V |
Maximum continuous voltage to Ground | 85000 V |
Time per tap change | 4 – 6 seconds |
Weight of tap changer without oil | 650 Kg |
Weight of tap changer with oil | 1810 Kg |
Impulse voltage between Tap changer to earth | 350 kVp(1.2/50 micro seconds) |
Impulse voltage between adjacent Contacts | 200 kVp |
Impulse voltage over pre selector | 200 kVp |
Impulse voltage between Selector and fine selector | 250 kVp |
Maximum voltage rating | 33 kV |
Maximum current rating | 1600 A |
Direction of power flow | Bi-Directional |
Tapping arrangement | Linear, coarse-fine, reversible |
OLTC design | Divertor switch |
Maximum Number of tap position | 33 |
Maximum recovery voltage | 20 kV (across reversing switch) |
Approximate time per tap change | 2 seconds |
Impulse test voltage to ground and between phases | 34 kV/110kVp(for all live parts to) |
Impulse voltage with stand | 26 kV/70kVp(across tapping range) |
Insulation between phase | 33 kV |
Insulation of all part to ground for continuous voltage | 33 kV |
Step voltage | 1000 V |
Power frequency withstand test voltage for all live parts to ground | 34 kV |
Power frequency with stand test voltage across tapping range | 26 kV |
Power frequency with stand voltage across one tap | 15 kV |
Maximum recovery voltage across reversing Switch | 20 kV |
Weight of OLTC without oil | 750 kg |
Oil quantity | 960 liters |